SHOP FOR L&L KILN PARTS

This is made of electrically insulating high temperature board. Stainless steel terminal bolts are assembled to the board with nuts and lock washers at the right dimensions for the element connections.
This is made of electrically insulating high temperature board. Stainless steel terminal bolts are assembled to the board with nuts and lock washers at the right dimensions for the element connections.
This is made of electrically insulating high temperature board. Stainless steel terminal bolts are assembled to the board with nuts and lock washers at the right dimensions for the element connections.
This is made of electrically insulating high temperature board. Stainless steel terminal bolts are assembled to the board with nuts and lock washers at the right dimensions for the element connections.
This is made of electrically insulating high temperature board. Stainless steel terminal bolts are assembled to the board with nuts and lock washers at the right dimensions for the element connections.

Power Terminal Strip - Unit has Two 1/4" Spade Terminals on each side and is used for the Power Wires on Liberty-Belle Kilns

Element Insulator Bushing - Unit is used in conjunction with the Old Style (Red) Element Terminal Boards to keep the Element insulated from the Sheet Metal Casing

MOV Surge Suppressor for 250 Volt / 50 Amp Enclosed Power Contactors - Unit is 5mm in Diameter, absorbs the discharge energy from the inductive coil of a contactor, and can be used on All 240 Volt or 208 Volt Contactors

The L-G-MOV1/00 MOV has a mark on it of PZ390 (you have to use a magnifying glass to see this).

Attach the MOV Suppressor to the Power Contactor by using two 16-14 AWG Insulated Female Slip on Wire Terminals for 1/4" Spades, one on each end of the MOV.

2 Pole Power Terminal Block - Unit is used on All Easy-Fire Kilns at any Voltage and 1 Phase Power. These are also used for 380-415/3 Phase Wye kilns that have a neutral by using two of them to create four connections.

2 Pole Power Connection Block - Units is rated for 175 Amps and is used with All Jupiter Automatic and Jupiter Manual Kilns at any Voltage and 1 Phase Power

3 Pole Power Connection Block - Units is rated for 175 Amps and is used with All Jupiter Automatic and Jupiter Manual Kilns at any Voltage and 3 Phase Power

1 Pole Power Connection Block - Unit is rated for 335 Amps and is used with DaVinci Kilns at 480 Volts or 380 Volts and 3 Phase Power that require an extra Power Connection

Noise Filter for Radio Frequency Noise - This is used to filter incoming power to prevent line noise from affecting the electronic control

25 Amp Enclosed Power Relay with a 12 Volt Coil - Unit is the standard Power Relay used on All Polygonal and X2300-D & XB2300-D Series Kiln Automatic Control Panels, it is also used as the Control Relay for X2800-D & XB2800-D, X3200-D & XB3200-D, T2300-D & TB2300-D, and T3400-D & TB3400-D Series DaVinci Kilns and Hercules and Easy-Load kilns. This contactor is used interchangeably as a power contactor on both 240 volt and 208 volt kilns. 

25 Amp Enclosed Power Relay with a 240 Volt Coil - Unit is the standard Power Relay used on All Newer Manual Kilns that Require Power Relays

 

Parts

See this page for the 12 Volt 30 Amp relay we use for most kilns.

See this page for the 240 Volt 30 Amp relay we use as a control relay for 480 volt kilns.

How to change a relay in an Easy-Fire Kilns

  1. Be sure to keep the wires on in the right sequence when changing a power or control relay in an Easy-Fire, Easy-Fire XT, School-Master or eQuad-Pro Kiln.
  2. The configuration is similar in a Jupiter panel or as control relay in a DaVinci, or Easy-Load panel.
  3. Make sure kiln is unplugged or locked out and tagged out at the circuit breaker or fused disconnect switch when doing this maintenance.

 

2 Pole Power Relay - Unit is rated for 30 Amps (resistive load below 300 Volts) with a 208 Volt Coil and is used in Older Manual Kilns and Renaissance Kilns at 208 Volts and any Phase Power