SHOP KILN PARTS
SUBCATEGORIES

30 Amp NEMA 6-30P Power Cord - Unit is 12' Long with a Three Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

50 Amp NEMA 6-50P Power Cord - Unit is 12' Long with a Three Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

30 Amp NEMA 10-30P Power Cord - Unit is 12' Long with a Three Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

30 Amp NEMA 14-30P Power Cord - Unit is 12' Long with a Four Prong Plug and is used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

50 Amp NEMA 14-50P Power Cord - Unit is 12' Long with a Four Prong Plug and can be used with All Liberty-Belle Kilns at any Voltage and 1 Phase Power

Used on European version vents, Chameleon, Fuego, Robin and Corona kilns. 15 amp.

Used on UK version vents, Chameleon kilns, Fuego, Robin and Corona kilns. 13 amp.


14 Pin Female Receptacle for Handheld Controls - Unit includes color coded wires for hook up in the Floor-Mounted Control Panel and is used in conjunction with the 14 Pin Male Plug

14 Pin Male Plug for Handheld Controls - Unit includes a 6' Long Cord with color coded wires at the end for hook up in the Handheld Box and is used in conjunction with the 14 Pin Female Receptacle

This is a set of components to move the cord connections on a DaVinci kiln ring to the outer element connection box.
The kit consists of:
- (1) Two Pole Terminal
- (1) Insulating board
- (2) Terminal Mounting Screws (#8 X 3/4" A Type
- (2) #10 SS nuts
- (2) #10 SS washers
- (2) #10 SS split washers
- (1) #10 X 1/2" Self-Tapping screw (ground screw)
- (1) #10 star washer (for the ground screw)
- (1) Ground Symbol Sticker
- (1) 12" length of wire insulator sleaving for covering the cord wires (this gets cut to length to slip over the cord wires)
- (2) 8 Gauge 150 Deg C 9" long Power Wires with a ring terminal to go the element connection and a stripped end to go in the new terminal block

Ceramic Element Connection Board for Kiln Sections with Three Elements - Unit includes terminal screw and all hardware.

Ground Wire Jumper Cord for Jupiter Kiln Element Boxes - Unit is 14 AWG, precut to 8", and comes fitted with one Ring Terminal and one Fork Terminal

Ground Wire Jumper for Piggybacked Control Panels - Unit is 10 AWG, precut, and comes with two Ring Terminals

Control Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled and labeled to run off of the DynaTrol Control Board for all Easy-Fire Kilns with two Sections.
Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Connection Block to the Power Relays on all Easy-Fire Kilns with two sections at any voltage and 1 Phase Power. There are four wires per set.
Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Terminal Strip to the Power Relays on all Easy-Fire Kilns with two sections at any voltage and 1 Phase Power. There are four wires in a set.

Control Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled and labeled to run off of the DynaTrol Control Board for all three section Easy-Fire Kilns.

Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Connection Block to the Power Relays on all Easy-Fire and School-Master Kilns with three sections at any voltage and 1 Phase Power. There are six wires in a set.

Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Connection Block to the Power Relays on all Easy-Fire and School-Master Kilns with three sections at any voltage and 3 phase power. There are six wires in a set.

Power Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled, and labeled to run from the Power Terminal Strip to the Power Relays on All Easy-Fire and School-Master Kilns with three sections at any voltage and phase power. There are six wires in a set.

Power Element Lead Wire Bottom Harness - Set of wires is precut, fitted with the appropriate terminal ends, and labeled to run from the Bottom Element Terminal Block to the Power Terminal Strip on All Three Section Easy-Fire and School-Master Kilns. There are two wires per set.

Power Element Lead Wire Bottom/Middle Harness - Set of wires is precut, fitted with the appropriate terminal ends, and labeled to run from the Bottom Element Terminal Block to the Power Terminal Strip on all Two Section kilns, or from the Middle Element Terminal Block to the Power Terminal Strip on all Three Section Easy-Fire and School-Master Kilns. There are two wires in a set.

Power Element Lead Wire Top Harness - Set of wires is precut, fitted with the appropriate terminal ends, and labeled to run from the Top Element Terminal Block to the Power Terminal Strip on All Easy-Fire and School-Master Kilns. There are two wires per set.

Control Wire Harness - Set of wires is precut, fitted with the appropriate terminal ends, bundled and labeled for the One-Touch Control Board for all three section School-Master Kilns (SM23T, SM23T-3 & SM28T-3).

14 Gauge Jumper Wire - Unit is 8" Long and includes Insulation Sleaving and two Ring Terminals
10 Gauge Jumper Wire - Unit is 8" Long and includes Insulation Sleaving and two Ring Terminals. This is used as a ground wire to ground the element connection box to the kiln case.

14 Gauge Jumper Wire - Unit is 10" Long and includes Insulation Sleaving and two Ring Terminals

14 Gauge Ground Wire - Unit is 8" Long and includes Insulation Sleaving, one Ring Terminal, and one Fork Terminal

Wire Sleeving for Jupiter Kiln Jumper Wires - Unit is used to provide an additional layer of insulation around the Power Wires in the Element Connection Box on All Jupiter Automatic and Jupiter Manual Kilns

High Temperature Wire Sleeving for DiVinci Kiln Jumper Wires - Unit is used to provide an additional layer of insulation around the power wires in the Element Connection Box on All DaVinci Kilns.

Control Wire Harness - Unit is precut, fitted with the appropriate terminal ends, bundled, and labeled to from off of the One-Touch

Element Jumper Wires - Unit is precut and fitted with the appropriate terminal ends to run from the Element Terminal Block on the Bottom Section to the Element Terminal Block on the Top Section

Element Connection Wires - Unit is precut and fitted with the appropriate terminal ends to run from the Element Terminal Block on the Top Section to the Power Terminal Strip located on the Insulation Plate

Primary Power Wires - Unit is precut and fitted with the appropriate terminal ends to run from the Power Relay to the Power Connection Block

Secondary Power Wires - Unit is precut and fitted with the appropriate terminal ends to run from the Power Relay to the Power Terminal Strip

MOV Surge Suppressor for 250 Volt / 50 Amp Enclosed Power Contactors - Unit is 5mm in Diameter, absorbs the discharge energy from the inductive coil of a contactor, and can be used on All 240 Volt or 208 Volt Contactors
The L-G-MOV1/00 MOV has a mark on it of PZ390 (you have to use a magnifying glass to see this).
Attach the MOV Suppressor to the Power Contactor by using two 16-14 AWG Insulated Female Slip on Wire Terminals for 1/4" Spades, one on each end of the MOV.

Ceramic Element Connection Block for M Series (middle section) Easy-Fire Kiln Sections - The unit includes the terminal screw, nuts, and stainless large flat washers. Used on e18M, e18M-3, e23M, e23M-3, e28M-3 middle kiln sections that are 4.5" high.

15 Amp NEMA 5-15P Power Cord - Unit is a 72" Long Cord and can be used at 120 Volts and 1 Phase Power

20 Amp NEMA 5-20P Power Cord - Unit is a 72" Long Cord and can be used at 120 Volts and 1 Phase Power

50 Amp NEMA 15-50P Power Cord - Unit is a 72" Long Cord with a Four Prong Plug and is used with All Easy-Fire Kilns at any Voltage and 3 Phase Power and All J1800 & JD1800, J23 & JD23, and J230 & JD230 Kilns at any Voltage and 3 Phase Power

50 Amp NEMA 6-50P Power Cord - Unit is a 72" Long Cord with a Three Prong Plug and is used with all Easy-Fire Kilns at any Voltage and 1 Phase Power, all J1800 & JD1800, J23 & JD23, and J230 & JD230 Kilns, all Dura-Fire kilns, and many other kilns at any Voltage and 1 Phase Power (Also used for retrofit on Older Econo J1400 Series Kilns)

50 Amp Jumper Cord with Insulated Sleaving on the ends - Unit is used with DaVinci X2800-D & XB2800-D, X3200-D & XB3200-D, T2300-D & TB2300-D, and T3400-D & TB3400-D Kilns at any Voltage and Phase Power

USE #1: 50 Amp Jumper Cord - Unit is used with DaVinci X3200-D & XB3200-D and T3400-D & TB3400-D Bell-Lift Kilns at 208 Volts or 240 Volts and any Phase Power. 12 feet long.
USE #2: This can also be used as a 12 foot 6-50 single phase 50 amp power cord for Easy-Fire, School-Master, Jupiter and other kilns that are 48 amps or less and single phase.
USE #2: This is an optional cord configuration for a Liberty-Belle kiln. Make sure the correct cord is being ordered as six other options are available (see Spec-Liberty-Belle.pdf). The 14-30P cord is standard on Liberty-Belle kilns.
12 foot 50 Amp Jumper Cord - Unit is used with DaVinci X3200-D & XB3200-D and T3400-D & TB3400-D Bell-Lift Kilns at 480 Volts and 3 Phase Power. There is no plug on this cord.


Red Pilot Light - Unit is used for All Manual Kiln Control Panels