The Best Thermocouple
- The standard thermocouple for DynaTrol or Genesis control is Type K, commonly an 8-gauge exposed Type K thermocouple used on various kiln models.
- For constant high-fire applications, a Type S platinum thermocouple with an alumina sheath is the best, standard on JH Series kilns and recommended for extreme conditions.
Technical Information
- Type S thermocouples have legs of platinum and rhodium, usable from 32°F to 2700°F (0°C to 1480°C).
- They last long at kiln temperatures up to 2400°F if not mechanically damaged.
- Lead wires for Type S are not interchangeable with Type K.
- DynaTrol controls made before Jan 1, 2006, and One-Touch controls cannot be retrofitted for Type S.
- DynaTrol 700 controls (post Jan 1, 2006) can be converted with a lead wire change.
Description:
- Type S thermocouples have a 5/16” OD alumina sheath and are ungrounded.
- Two lengths are available:
- 120 mm (4.75”) for Easy-Fire, Jupiter, eQuad-Pro, JH Series, DaVinci, and Doll kilns.
- 160 mm (6.3”) for Easy-Load front-loading kilns.
- Polarity:
- Black Wire = PLUS (+)
- Red Wire = MINUS (-)
Ordering:
Part Number: T-G-SXXX/00
- Type-S Thermocouple - 120 mm (Standard Length).
- Type S Platinum Thermocouple with Alumina Protection Tube and Terminal Block.
- 120 mm (4-3/4”) Long x 1/4” Diameter.
- Suitable for kilns with 2-1/2” or 3” brick insulation.
- Not for use on front-loading kilns or custom kilns with more than 3” insulation.
- hotkilns.com/type-s-thermocouple-standard
Part Number: T-G-SXXX/06
- Type-S Thermocouple - 160 mm (Medium Length).
- Type S Platinum Thermocouple with Alumina Protection Tube and Terminal Block.
- 160 mm (6-5/16”) Long x 1/4” Diameter.
- Used on Easy-Load kilns with 5” wall thickness.
- hotkilns.com/type-s-thermocouple-long
- Type S thermocouples can be ordered with any kiln having a DynaTrol or Genesis Control.
Retrofitting Cautions:
- Check the configuration of any replacement control to avoid melting your kiln.
- Replacement controls typically have the standard configuration for Type K thermocouples with 3-zone control.
- Ensure the control configuration matches your thermocouple type.
- Incorrect configuration (Type S thermocouples with Type K control) can cause severe over firing to the point of melting the elements, element channels and brick.
- Type K thermocouple extension wire is yellow or brown; Type S extension wire is green (in the USA).
- For more information on thermocouple wires and hookup, visit hotkilns.com/tc-polarity.