How to check the operation of a control transformer on an L&L automatic kiln. Applies to all automatic kilns that are not 480 volts. The control transformer reduces the incoming line voltage from 240, 208 or 220 volts to 24 volts for the control and 12 volts for the relays. See this page for more detail.

Parts
  • See this page for 12 KVA control transformers used on kilns with three sections or less.
  • See this page for 30 KVA control transformers used on kilns with four or more sections.
  • The most important debugging tool in any toolbox is a trusty multimeter. A multimeter can measure continuity, resistance, voltage and sometimes even current, capacitance, temperature, etc.

    In this video we will demonstrate how to upgrade your kiln from Type K thermocouples to Type S.

    In this video we demonstrate how to replace Type K thermocouples. These thermocouples degrade over time, and we recommend replacing them whenever you replace your elements. 

    How To Change A Relay
  • When changing a power or control relay in an Easy-Fire, Easy-Fire XT, School-Master, or eQuad-Pro Kiln, be sure to keep the wires in the right sequence.
  • The configuration is similar to a Jupiter panel or as a control relay in a DaVinci or Easy-Load panel.
  • When performing this maintenance, make sure the kiln is unplugged or locked out and tagged out at the circuit breaker or fused disconnect switch.
  • For more information see this page
  • Parts

    See this page for the 12-Volt 30-Amp relay we use for most kilns.

    This page describes the 240-volt 30-amp relay we use as a control relay for 480-volt kilns.