A replacement DynaTrol or Genesis control typically features our standard configuration, which includes Type K thermocouples and a 3-zone control. THIS MAY NOT MATCH YOUR KILN! Here is what you need to check:
CHECK THE THERMOCOUPLE TYPE
This is the MOST IMPORTANT thing to do. If your kiln has type S thermocouples and the control is set up for type K thermocouples, you could overfire the kiln to the point of a complete melt-down.
Don't let this happen:
Type K thermocouple extension wire, which connects the thermocouple to the control, is either yellow or brown. Type S extension wire is typically green in the USA.
See this for more information on thermocouple wires and hookup: check-polarity-thermocouples-and-lead-wires
Type K thermocouples typically look like this.
Type S thermocouples typically look like this.
Type K Pyrocil thermocouples typically resemble this.
HOW MANY ZONES DO YOU HAVE?
Count the number of thermocouples you have – that should equal the number of zones configured in the DynaTrol. To change the number of zones for which the DynaTrol is configured, see these instructions: hotkilns.com/hidden-menu-dynatrol and then How to change zones on a DynaTrol. If you have a Genesis: How to change zones on a Genesis.
CHECK THE THERMOCOUPLE OFFSET
If you have Type S thermocouples then the Thermocouple Offset should be set for 00.00.
If you have Type K thermocouples and a ceramic protection tube is present, the Thermocouple Offset should typically be set to 00.18 (18°F).
If you have Pyrocil sheathed Type K thermocouples or 14 gauge or 8 gauge thermocouples without a ceramic protection tube, then the Thermocouple Offset should be set for 00.00
How to change Change Thermocouple Offset of a DynaTrol or Change Thermocouple Offset on a Genesis
HOW TO CHANGE THE CONTROL IN THE KILN
See this video: replace-control