LOOK IN THE HIDDEN OTHER MENU ON YOUR DYNATROL
This menu contains the programmable settings for the rest of the features in the DynaTrol. To find this menu, first IdLE and tC(#), and the current temperature must be cycling in the display. Note: If you only have one thermocouple enabled then you will not see TC(#)
Press |
Display |
Comment
|
OTHER |
RSET |
(this is the first option in the Hidden Other Menu)
|
4 and 4 and 3 |
NOTC |
This is the first hidden menu item. If you want to change this setting hit ENTER if you want to go to the next hidden menu item press OTHER
|
OTHER |
Various options will show up (See below) |
Press Other to scroll through the options.
|
START/STOP |
|
Exits the Hidden Menu
|
ERTF: Stores the Temp, Hours Past, and Rate of Rise when an Error Code occurs. This feature stores the temp, the number of hours that have passed in the program, and the rate of rise of the kiln when an error code occurs. If you come into your kiln and see E-1 for example, it has shut off because it cannot climb faster than the slowest allowable temp:12 degrees per hour. You can press ENTER and then go to ERTF in the Hidden Other Menu, press ENTER there and see, the temperature at which the error code happened, then the number of hours and minutes that have passed since the program began, then the actual rate of rise in degrees F/ hour (or degrees C/ hour if yours is set for Celsius) when the error code occurred. This is a great diagnostic tool.