Check Power Relay
- One way to easily check relays is to look at the kiln elements through the peepholes when the kiln is firing. If you know your elements are OK after having done an ohm test and the elements are not glowing then you should suspect the relays.
- Another way to check the relays (or bad elements) is to check the temperatures of each zone by pressing "1", "2" and "3" in sequence and recording the temperatures of each thermocouple at intervals over the length of the firing. If one zone is consistently firing at a lower temperature then you probably have either burned out elements or a bad relay.
- If the relay does not make a soft clicking noise when the kiln is turned on try turning the kiln off and on and then restarting the program.
- Remove panel.
- Set your multi-meter the approximately 24 volts AC. Check the voltage coming into the coil of the Power Relay. You can tell which wires these are because they will be the small wires coming from the control. This test will tell you if you are getting power to the relay coil which actuates the relay. Unless the relay is actuated by the control you will get no output from the power side of the relay.
- With panel plugged in and firing check output from Power Relay with your digital multi-meter. The meter should be set to the next highest voltage above 240 volts AC. Output should be approximately the rated voltage of the kiln when it is supposed to be calling for power to the elements.
CAUTION: LIVE ELECTRICITY IS INVOLVED WITH SOME OF THESE TESTS. This test should only be done by an experienced person familiar with electricity.