user warning: Expression #1 of ORDER BY clause is not in SELECT list, references column 'hotkilns_live.n.created' which is not in SELECT list; this is incompatible with DISTINCT query: SELECT DISTINCT n.nid, n.vid, n.title FROM content_field_knowledgebase_actions nr INNER JOIN node n ON n.vid = nr.vid AND n.status = 1 INNER JOIN node_access na ON na.nid = n.nid WHERE (na.grant_view >= 1 AND ((na.gid = 0 AND na.realm = 'all') OR (na.gid = 0 AND na.realm = 'content_access_author') OR (na.gid = 1 AND na.realm = 'content_access_rid'))) AND ( nr.field_knowledgebase_actions_nid = 1169 )ORDER BY n.created DESC in /home/hotkilns/public_html/sites/all/modules/nodereferrer/nodereferrer.module on line 428.
Replacing a Control Transformer in an L&L Automatic Kiln

Click on image to enlarge

  1. Unplug kiln.
  2. Remove the control box and remove the insulation panel.
  3. Using needle nose pliers pull of the wires from the transformer. It can take significant force to remove the spade connectors.
  4. Unscrew the two nuts that hold the control transformer onto the panel and remove the transformer.
  5. Before installing the new transformer put the small jumper wire onto terminals #2 and #3 on the bottom row of terminals. Note the little numbers by the contacts.