There are some differences in the 600 series DynaTrol board and the 700 series DynaTrol board.

  1. The two spades AC 1 and AC 2 are in different locations.  Question: Do we change the order of wires positions so the AC1 wire is to the relocated position? (Answer: Keep using the the same contacts and ignore their location)
  2. There is a spade marked “Safety” on the new board. Do we ignore this point or do we need to do something different? (Answer: Ignore this contact)

Note the 700 series board has been used since January 2006. The 600 level board was used from April 2003 to December 2005.